STANDARD FUNCTION | DEscriptION OF FUNCTIONS |
1.Lack of phase, error phase protection | If lack of ohase or error phase has beeen checked out, the moving walk will automatically stop the operation. |
2.Motor over-load protection | When the current exceeds 15% of the current rating, the moving walk will automatically stop the operation. |
3.Electrical appliance loop protection | It offers the automatic circuit disconnecting device to protet the circuit and mains components of the moving walk. |
4.Handrail inlet protection | When some foreign substance has been clippped in the handrail inlet, the moving walk will automatically stop the operation. |
5.Comb plate safety device | When some foreign substance has been clippped in or between the combs, the movign walk will automatically stop the operation. |
6.step sagging protection device | When there is abnormal step bending, the moving walk will stop the operation before the step intering into the comb plate. |
7.Broken drive-chain safety device | When the drive-chain has been over-stretched or it is broken, the moving walk will automatically stop the operation. |
8.Broken step chain protection | When the step (plate) chain has been over-stretched or it is broken, the moving walk will automatically stop the operation. |
9.Over-speed protection | When there is over-speed to the moving walk, it will automatically stop the operation. |
10.Direction reversal protection | When it comes the unintentional reversal of the direction of travel, the moving walk will automatically stop the operation. |
11.Security line | The yellow synthetic resin security line is located in the front position and two sides of the moving walk tread so that the passengers will not tread in-between the edge of the adjacent step and the lift group lengthened skirt panel. The security line on both sides of the step is higher than the read surface. (The moving walk offers the selective yellow spray -painted security line.) |
12.Emergency stop button | When the button has been pressed down, the moving walk will stop the operation. |
13.Skirt panel protection | When some foreign substance has been clipped in between the skirt panel and the step, the moving walk will automatically stop the operation. |
14.Brake protection | When the electric force falls short of supply or it acts any of the safety device, the brake function goes into effect by the safety device through the spring resilience action. In this way, the moving walk stops the operation. |
15.Safety inspection switch | It is a safety device to prevent from the moving walk staring during the inspection and maintenance. |
16.Step illumination | Illumination exists in the upper and lower ends of the moving walk, in the lower part of the step in order to remind the passenger of the security matters. |
17.Alarm bell starting device | The alarm bell rings when it stars the moving walk in order to remind the passengers of the security matters. |
18.Control device for handrail breakage | When the handrail is broken, the moving walk will automatically stop the operation. |
19.Skirt panel brush | The brush that has been installed between the skirt panel and the step will prevent the passengers from touching the skirt panel. (It is not merely restricted to the moving walk.) |
OPTION FUNCTIONS | DEscriptION OF FUNCTIONS |
20.VVVF variable frequency energy-saving system | When chooses the frequency converter, it can effectively reduce the energy consumption. |
21.Comb illumination | The illumination has been installed in the skirt panel near the comb plate. It offers the lighting for the step and the comb plate. It is more convenient for the passengers to up and doen the moving walk. |
22. Handrail illumination | The handrail illumination has been installed in the handrail frame. The gentle light adds charm to the running moving walk. |
23.Automatic start/stop | The infrared ray sensor which is near the floor plate can detect the passenger that enter into the floor plate. Then it will automatically start the operation. After all the passengers leave, it will automatically stop the operation again in order to save the energy loss. Scaning sensor and traditional guide rod are available for your choice. |